Pump Specifications
LE100-Series
1HP Submersible Sewage Pump
0
5
10
15
20
25
30
35
40
0
20
40
60
80
100
120
140
GALLONS PER MINUTE
TO
TAL
HE
AD
I
N
FEE
T
0
2
4
6
8
10
12
0
2
4
6
8
LITERS PER SECOND
TO
TA
L H
E
AD
I
N
M
E
TER
S
LE100-P1 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
LE100-Series Dimensional Data
LE100-P2 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
LE100-Series Electrical Data
MODEL HP
VOLTAGE
PHASE SF
FULL
LOAD
AMPS
LOCKED
ROTOR
AMPS
THERMAL
OVERLOAD
TEMP
STATOR
WINDING
CLASS
CORD
LENGTH
FT
DISCHARGE AUTOMATIC
LE102A2 1 208-230 1 1.00 8
21 105°C 221°F
B
10
2" Flanged
YES
LE102A2-2 1 208-230
1 1.00 8
21 105°C 221°F
B 25
2"
Flanged
YES
LE102M2 1 208-230
1 1.00 8
21 105°C 221°F
B 10
2"
Flanged NO
LE102M2-2 1 208-230
1 1.00 8
21 105°C 221°F
B 25
2"
Flanged NO
LE102A3 1 208-230
1 1.00 8
21 105°C 221°F
B 10
3"
Flanged
YES
LE102A3-2 1 208-230
1 1.00 8
21 105°C 221°F
B 25
3"
Flanged
YES
LE102M3 1 208-230
1 1.00 8
21 105°C 221°F
B 10
3"
Flanged NO
LE102M3-2 1 208-230
1 1.00 8
21 105°C 221°F
B 25
3"
Flanged NO
LE103M2-2 1 208-230
3 1.00 5.3 17.5
N/A
B
25 2"
Flanged NO
LE103M3-2 1 208-230
3 1.00 5.3 17.5
N/A
B 25
3"
Flanged NO
LE104M2-2 1 440-480
3
1.00 2.5
8.5
N/A
B 25
2"
Flanged NO
LE104M3-2 1 440-480
3
1.00 2.5
8.5
N/A
B 25
3"
Flanged NO
LE105M2-2 1
575
3
1.00 1.9
7.0
N/A
B 25
2"
Flanged NO
LE105M3-2 1
575
3
1.00 1.9
7.0
N/A
B 25
3"
Flanged NO
LE100-Series Technical Data
IMPELLER
2 VANE CLASS 25 CAST IRON
SOLIDS HANDLING SIZE
2"
PAINT
POWDER COAT
MAX LIQUID TEMP
60°C 140°C
MAX STATOR TEMP
130°C 266°C
THERMAL OVERLOAD
105°C 221°F (single-phase only)
POWER CORD TYPE
SJTW (1-PH) or SEOOW (3-PH)
MOTOR HOUSING
CLASS 25 CAST IRON
VOLUTE
CLASS 25 CAST IRON
SHAFT
STAINLESS
HARDWARE
STAINLESS
ORINGS
BUNA N
MECHANICAL SEAL
UNITIZED CERAMIC CARBON
MIN BEARING LIFE
50,000 HRS
WEIGHT
64 LBS
LE100-P3 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
LE100-Series Specifications
1.01 GENERAL:
The contractor shall provide labor, material, equipment, and incidentals required to provide (QTY) centrifugal pumps as specified
herein. The pump models covered in this specification are Series LE100 single phase or three phase pumps. The pump furnished for this
application shall be model ______________as manufactured by Liberty pumps.
2.01 OPERATING CONDITIONS:
Each submersible pump shall be rated at 1 hp_____ volts _______ phase 60 Hz. 3450 RPM. The unit shall produce ______G.P.M. at
______ feet of total dynamic head.
The submersible pump shall be capable of handling residential sewage with 2" solid handling capability. The submersible pump shall have
a shut-off head of 36 feet and a maximum flow of 150 GPM @ 12 feet of total dynamic head.
The pump shall be controlled with:
______A piggy back style on/off float switch.
______A NEMA 4X outdoor simplex control panel with three float switches and a high water alarm.
______A NEMA 1 indoor simplex control panel with three float switches and a high water alarm.
______A NEMA 4X outdoor duplex control panel with three float switches and a high water alarm.
______A NEMA 1 indoor duplex control panel with three float switches and a high water alarm.
______A NEMA 4X outdoor duplex control panel with four float switches and a high water alarm.
______A NEMA 1 indoor duplex control panel with four float switches and a high water alarm.
3.01 CONSTRUCTION:
Each centrifugal sewage pump shall be equal to the
certified Series LE100 SERIES pumps as manufactured by Liberty Pumps,
Bergen NY. The castings shall be constructed of class 25 cast iron. The motor housing shall be oil filled to dissipate heat. Air filled motors
shall not be considered equal since they do not properly dissipate heat from the motor. All mating parts shall be machined and sealed
with a Buna-N o-ring. All fasteners exposed to the liquid shall be stainless steel. The motor shall be protected on the top side with sealed
cord entry plate with molded pins to conduct electricity eliminating the ability of water to enter internally through the cord. The motor shall
be protected on the lower side with a unitized ceramic/carbon seal with stainless steel housings and spring. The upper and lower bearing
shall be capable of handling all radial and thrust loads. The pump shall be furnished with stainless steel handle.
4.01 ELECTRICAL POWER CORD
The submersible pump shall be supplied with 10 or 25 feet of multiconductor power cord. It shall be cord type SJTW (1-PH) or SEOOW (3-
PH), capable of continued exposure to the pumped liquid. The power cord shall be sized for the rated full load amps of the pump in
accordance with the National Electric Code. The power cable shall not enter the motor housing directly but will conduct electricity to the
motor by means of a water tight compression fitting cord plate assembly, with molded pins to conduct electricity. This will eliminate the
ability of water to enter internally through the cord, by means of a damaged or wicking cord.
LE100-P4 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
LE100-P5 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
5.01 MOTORS
Single phase motors shall be oil filled, permanent split capacitor, class B insulated NEMA B design, rated for continuous duty. Three
phase motors shall be oil filled, class B insulated NEMA B design, rated for continuous duty. At maximum load the winding temperature
shall not exceed 130 degrees C unsubmerged. Since air filled motors are not capable of dissipating heat they shall not be considered
equal. Single phase pump motors shall have an integral thermal overload switch in the windings for protecting the motor. Three phase
motors shall be used with an appropriate controller with integral overload protection. The capacitor circuit shall be mounted internally in
the pump on single phase units.
6.01 BEARINGS AND SHAFT
Upper and lower ball bearings shall be required. The bearings shall be a single ball / race type bearing. Both bearings shall be
permanently lubricated by the oil, which fills the motor housing. The motor shaft shall be made of 300 or 400 series stainless steel and
have a minimum diameter of .625".
7.01 SEALS
The pump shall have a unitized carbon / ceramic seal with stainless steel housings and spring equal to Crane Type 6A. The motor plate /
housing interface shall be sealed with a Buna-N o-ring.
8.01 IMPELLER
The impeller shall be a class 25 iron, with pump out vanes on the back shroud to keep debris away from the seal area. It shall be
threaded to the motor shaft.
9.01 CONTROLS
All single phase units can be supplied with CSA and UL approved automatic wide angle tilt float switches. The switches shall be equipped
with piggy back style plug that allows the pump to be operated manually without the removal of the pump in the event that a switch
becomes inoperable. Manual Pumps are operable by means of a pump control panel.
10.01 PAINT
The exterior of the casting shall be protected with Powder Coat paint.
11.01 SUPPORT
The pump shall have cast iron support legs, enabling it to be a free standing unit. The legs will be high enough to allow 2" solids to enter
the volute.
12.01 SERVICEABILTY
Components required for the repair of the pump shall be shipped within a period of 24 hours.
LE100-P6 R7/15/2008 ©Copyright 2008 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
13.01 FACTORY ASSEMBLED TANK SYSTEMS WITH GUIDE RAIL AND QUICK DISCONNECT DISCHARGE
______ Guide factory mounted rail system with pump suspended by means of bolt on quick disconnect which is sealed by means of nitrile
grommets or o-rings. The disconnect system shall have an internal ball check. The Discharge piping shall be schedule 80 PVC and
furnished with a PVC shut-off ball valve. The Tank shall be wound fiberglass or roto-molded plastic. A cast iron inlet hub shall be provided
with the fiberglass systems.
______ Stainless steel Guide Rail
______ Zinc plated steel Guide Rail
______ "diameter of basin size
______ "height of basin size
______ "distance from top of tank to discharge pipe outlet
______ Fiberglass cover
______ Structural foam polymer cover
______ Steel cover
______ Simplex System with Outdoor panel and alarm
______ Duplex System with Outdoor panel and alarm
______ Simplex System with Indoor panel and alarm
______ Duplex System with Indoor panel and alarm
______ Separate Outdoor Alarm
______ Remote Outdoor Alarm
______ Separate Indoor Alarm
______ Remote Indoor Alarm
14.01 TESTING
The pump shall have a ground continuity check and the motor chamber shall be Hi-potted to test for electrical integrity, moisture content
and insulation defects. The motor and volute housing shall be pressurized, and an air leak decay test is performed to ensure integrity of
the motor housing. The pump shall be run, voltage current monitored, and the tester checks for noise or other malfunction.
15.01 QUALITY CONTROL
The pump shall be manufactured in an ISO 9001 certified Facility.
16.01 WARRANTY
Standard limited warranty shall be 2 years.
...